It is divided into 4 zones:
· Left. Contains the information of the parameters used by the test, such as scanning distance, width and height of the screen, strategy used, size of the radii in pixels, millimeter and degrees (relative to the scanning distance), speed of the core in millimeters per second and in degrees per second.
· Drop-down curtain. Located on the left, it has all the elements to consult the results of the test, as well as to modify or repeat a radius. For this purpose, a list has been designed with the results obtained and scan data: scan distance, screen size, strategy used, as well as the elements to save the results in the database.
· Central, where the scanning screen of the diplopia field itself is located. The grid that configures it cannot be modified.
· Right, where the buttons necessary to cover the different tasks during the scan are located. It has been included:
- Selector to choose between the type of field to be performed:
§ Field of gaze.
§ Binocular field.
§ Diplopia field.
Any combination of the 3 types can be selected.
- Configurator of the test parameters, including:
§ Velocity in degrees per second.
§ Velocity in millimeters per second.
§ Time to travel a radius.
§ Height and width of the core.
§ Core area.
§ Witness shape selector: rectangle or oval.
§ Selector for common Goldmann sizes: V, IV, III, II and I.
§ Selector to choose whether stopping the token continues the movement from the beginning or from the current location.
§ Selector to view the axes of the selected point.
§ Selector to display and hide the test frame.
- Button to completely initialize the test.
- Command area for the execution of the test, including:
§ Panel with scan lines and their corresponding activation key: 1, 2, 3, 4, 5, 6, 7, 8, 9, Q, W, 0, E, R, T, Y, U, I, O, P, A, S, and D.
§ Selector of the direction of movement of the token: from outside to center or from center to outside.
§ Circles to position the token on the right edge, in the center or on the left edge.
§ Commands to start, stop and continue the baton movement.
§ Selector to choose whether to move the token along the lines or completely free.
§ Commands to mark the position of the token according to the selected test type: Gaze field (Left->F3, Right->F4), Binocular field (Left->F5, Right->F6) and Diplopia field (Left->F7, Right->F8),
§ Command to end each point (F12).
§ Command to accept the scan.
Annexes F-01, F-02, F-03, F-04, F-05 and F-06 show the characteristics and drawing of this screen.